[Mellanox] Add N/A as a valid fan direction for Nvidia platforms (#17930)
- Why I did it On some Nvidia platforms, fan direction could not be determined. Therefore 'N/A' becomes a valid value for those cases. - How I did it Add 'N/A' to the valid fan direction mapping, to avoid an error in the log. - How to verify it Check fan direction on Nvidia platforms, and make sure there aren't errors in the log.
This commit is contained in:
parent
2244aa2d7b
commit
8a7e38b3a3
@ -46,9 +46,11 @@ CONFIG_PATH = "/var/run/hw-management/config"
|
||||
FAN_DIR = "/var/run/hw-management/thermal/fan{}_dir"
|
||||
FAN_DIR_VALUE_EXHAUST = 0
|
||||
FAN_DIR_VALUE_INTAKE = 1
|
||||
FAN_DIR_VALUE_NOT_APPLICABLE = 2
|
||||
FAN_DIR_MAPPING = {
|
||||
FAN_DIR_VALUE_EXHAUST: FanBase.FAN_DIRECTION_EXHAUST,
|
||||
FAN_DIR_VALUE_INTAKE: FanBase.FAN_DIRECTION_INTAKE,
|
||||
FAN_DIR_VALUE_NOT_APPLICABLE: FanBase.FAN_DIRECTION_NOT_APPLICABLE,
|
||||
}
|
||||
|
||||
class MlnxFan(FanBase):
|
||||
@ -170,7 +172,7 @@ class PsuFan(MlnxFan):
|
||||
Retrieves the fan's direction
|
||||
|
||||
Returns:
|
||||
A string, either FAN_DIRECTION_INTAKE or FAN_DIRECTION_EXHAUST
|
||||
A string, either FAN_DIRECTION_INTAKE or FAN_DIRECTION_EXHAUST or FAN_DIRECTION_NOT_APPLICABLE
|
||||
depending on fan direction
|
||||
|
||||
Notes:
|
||||
@ -181,6 +183,7 @@ class PsuFan(MlnxFan):
|
||||
Air flow from QSFP side to fans side, for example: MSN2700-CS2R
|
||||
which means exhaust in community
|
||||
According to hw-mgmt:
|
||||
2 stands for N/A, in case fan direction could not be determined
|
||||
1 stands for forward, in other words intake
|
||||
0 stands for reverse, in other words exhaust
|
||||
"""
|
||||
@ -275,7 +278,7 @@ class Fan(MlnxFan):
|
||||
Retrieves the fan's direction
|
||||
|
||||
Returns:
|
||||
A string, either FAN_DIRECTION_INTAKE or FAN_DIRECTION_EXHAUST
|
||||
A string, either FAN_DIRECTION_INTAKE or FAN_DIRECTION_EXHAUST or FAN_DIRECTION_NOT_APPLICABLE
|
||||
depending on fan direction
|
||||
|
||||
Notes:
|
||||
@ -286,6 +289,7 @@ class Fan(MlnxFan):
|
||||
Air flow from QSFP side to fans side, for example: MSN2700-CS2R
|
||||
which means exhaust in community
|
||||
According to hw-mgmt:
|
||||
2 stands for N/A, in case fan direction could not be determined
|
||||
1 stands for forward, in other words intake
|
||||
0 stands for reverse, in other words exhaust
|
||||
"""
|
||||
|
Loading…