[201911] DellEMC S6100 SSD Monitor additional changes (#7291)
Why I did it Added soft-reboot plugin support. Added SSD version s16425cq check Added error message to display in console/SSH in case reboot is called in faulty/non-upgraded devices.
This commit is contained in:
parent
39e978bf75
commit
6204a1d809
@ -10,6 +10,7 @@ s6100/scripts/platform_reboot_override usr/share/sonic/device/x86_64-dell_s6100_
|
||||
s6100/scripts/fast-reboot_plugin usr/share/sonic/device/x86_64-dell_s6100_c2538-r0
|
||||
s6100/scripts/track_reboot_reason.sh usr/share/sonic/device/x86_64-dell_s6100_c2538-r0
|
||||
s6100/scripts/warm-reboot_plugin usr/share/sonic/device/x86_64-dell_s6100_c2538-r0
|
||||
s6100/scripts/soft-reboot_plugin usr/share/sonic/device/x86_64-dell_s6100_c2538-r0
|
||||
s6100/scripts/override.conf /etc/systemd/system/systemd-reboot.service.d
|
||||
common/dell_lpc_mon.sh usr/local/bin
|
||||
s6100/scripts/s6100_ssd_mon.sh usr/local/bin
|
||||
|
@ -1,10 +1,16 @@
|
||||
#!/bin/bash
|
||||
SSD_FW_UPGRADE="/host/ssd_fw_upgrade"
|
||||
|
||||
_error_msg(){
|
||||
echo "The SSD on this unit is faulty. Do not power-cycle/reboot this unit!"
|
||||
echo "soft-/fast-/warm-reboot is allowed."
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty. Do not power-cycle/reboot this unit!"
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "soft-/fast-/warm-reboot is allowed."
|
||||
}
|
||||
|
||||
# Check SSD Status
|
||||
if [ -e $SSD_FW_UPGRADE/GPIO7_low ] || [ -e $SSD_FW_UPGRADE/GPIO7_error ] || [ -e $SSD_FW_UPGRADE/GPIO_pending_upgrade ]; then
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty and does not support cold reboot."
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "Please perform a soft-/fast-/warm-reboot instead"
|
||||
if [ -e $SSD_FW_UPGRADE/GPIO7_low ] || [ -e $SSD_FW_UPGRADE/GPIO7_error ] || [ -e $SSD_FW_UPGRADE/GPIO7_pending_upgrade ]; then
|
||||
_error_msg
|
||||
exit 1
|
||||
fi
|
||||
|
||||
@ -19,8 +25,7 @@ if [ -e $SSD_FW_UPGRADE/GPIO7_high ]; then
|
||||
if [ $GPIO_STATUS == "0x01" ];then
|
||||
exit 0
|
||||
else
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty and does not support cold reboot."
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "Please perform a soft-/fast-/warm-reboot instead"
|
||||
_error_msg
|
||||
exit 1
|
||||
fi
|
||||
fi
|
||||
|
@ -10,8 +10,8 @@ if [ -e $SSD_FW_UPGRADE/GPIO7_high ]; then
|
||||
GPIO_STATUS=$(echo "$iSMART_CMD" | grep GPIO | awk '{print $NF}')
|
||||
|
||||
if [ $GPIO_STATUS != "0x01" ];then
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty and does not support cold reboot."
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "If a reboot is required, please perform a soft-/fast-/warm-reboot."
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty. Do not power-cycle/reboot this unit!"
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "soft-/fast-/warm-reboot is allowed."
|
||||
rm -rf $SSD_FW_UPGRADE/GPIO7_*
|
||||
touch $SSD_FW_UPGRADE/GPIO7_low
|
||||
systemctl stop s6100-ssd-monitor.timer
|
||||
|
@ -18,10 +18,15 @@ SSD_UPGRADE_LOG="$SSD_FW_UPGRADE/upgrade.log"
|
||||
SMART_CMD=`smartctl -a /dev/sda`
|
||||
|
||||
SSD_FW_VERSION=$(echo "$SMART_CMD" | grep "Firmware Version" | awk '{print $NF}')
|
||||
SSD_FW_VERSION=${SSD_FW_VERSION,,}
|
||||
SSD_MODEL=$(echo "$SMART_CMD" | grep "Device Model" | awk '{print $NF}')
|
||||
|
||||
if [ -e $SSD_FW_UPGRADE/GPIO7_pending_upgrade ]; then
|
||||
if [ $SSD_FW_VERSION == "S141002C" ] || [ $SSD_FW_VERSION == "S16425c1" ]; then
|
||||
if [ $SSD_MODEL == "3IE" ] && [ $SSD_FW_VERSION == "s141002c" ]; then
|
||||
# If SSD Firmware is not upgraded
|
||||
exit 0
|
||||
fi
|
||||
if [ $SSD_FW_VERSION == "s16425c1" ] || [ $SSD_FW_VERSION == "s16425cq" ]; then
|
||||
# If SSD Firmware is not upgraded
|
||||
exit 0
|
||||
fi
|
||||
@ -51,33 +56,37 @@ elif [ $SSD_UPGRADE_STATUS2 == "2" ];then
|
||||
|
||||
echo "$0 `date` Upgraded to unknown version after second mp_64 upgrade." >> $SSD_UPGRADE_LOG
|
||||
|
||||
elif [ $SSD_FW_VERSION == "S141002G" ] || [ $SSD_FW_VERSION == "S16425cG" ]; then
|
||||
elif [ $SSD_FW_VERSION == "s141002g" ] || [ $SSD_FW_VERSION == "s16425cg" ]; then
|
||||
# If SSD Firmware is upgraded
|
||||
GPIO_STATUS=$(echo "$iSMART_CMD" | grep GPIO | awk '{print $NF}')
|
||||
|
||||
if [ $GPIO_STATUS != "0x01" ];then
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty and does not support reboot."
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "If a reboot is required, please perform a soft-/fast-/warm-reboot."
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty. Do not power-cycle/reboot this unit!"
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "soft-/fast-/warm-reboot is allowed."
|
||||
rm -rf $SSD_FW_UPGRADE/GPIO7_*
|
||||
touch $SSD_FW_UPGRADE/GPIO7_low
|
||||
echo "$0 `date` The SSD on this unit is faulty and does not support cold reboot." >> $SSD_UPGRADE_LOG
|
||||
echo "$0 `date` If a reboot is required, please perform a soft-/fast-/warm-reboot." >> $SSD_UPGRADE_LOG
|
||||
echo "$0 `date` The SSD on this unit is faulty. Do not power-cycle/reboot this unit!" >> $SSD_UPGRADE_LOG
|
||||
echo "$0 `date` soft-/fast-/warm-reboot is allowed." >> $SSD_UPGRADE_LOG
|
||||
|
||||
else
|
||||
rm -rf $SSD_FW_UPGRADE/GPIO7_*
|
||||
touch $SSD_FW_UPGRADE/GPIO7_high
|
||||
fi
|
||||
if [ $SSD_UPGRADE_STATUS1 == "0" ]; then
|
||||
rm -rf $SSD_FW_UPGRADE/GPIO7_*
|
||||
touch $SSD_FW_UPGRADE/GPIO7_high
|
||||
systemctl start --no-block s6100-ssd-monitor.timer
|
||||
|
||||
systemctl start --no-block s6100-ssd-monitor.timer
|
||||
if [ $SSD_MODEL == "3IE" ];then
|
||||
echo "$0 `date` SSD FW upgraded from S141002C to S141002G in first mp_64." >> $SSD_UPGRADE_LOG
|
||||
else
|
||||
echo "$0 `date` SSD FW upgraded from S16425c1 to S16425cG in first mp_64." >> $SSD_UPGRADE_LOG
|
||||
fi
|
||||
elif [ $SSD_UPGRADE_STATUS2 == "1" ]; then
|
||||
rm -rf $SSD_FW_UPGRADE/GPIO7_*
|
||||
touch $SSD_FW_UPGRADE/GPIO7_low
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty. Do not power-cycle/reboot this unit!"
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "soft-/fast-/warm-reboot is allowed."
|
||||
|
||||
if [ $SSD_UPGRADE_STATUS1 == "0" ]; then
|
||||
if [ $SSD_MODEL == "3IE" ];then
|
||||
echo "$0 `date` SSD FW upgraded from S141002C to S141002G in first mp_64." >> $SSD_UPGRADE_LOG
|
||||
else
|
||||
echo "$0 `date` SSD FW upgraded from S16425c1 to S16425cG in first mp_64." >> $SSD_UPGRADE_LOG
|
||||
echo "$0 `date` SSD entered loader mode in first mp_64 and upgraded to latest version after second mp_64." >> $SSD_UPGRADE_LOG
|
||||
fi
|
||||
elif [ $SSD_UPGRADE_STATUS2 == "1" ]; then
|
||||
echo "$0 `date` SSD entered loader mode in first mp_64 and upgraded to latest version after second mp_64." >> $SSD_UPGRADE_LOG
|
||||
fi
|
||||
|
||||
else
|
||||
@ -85,13 +94,13 @@ else
|
||||
rm -rf $SSD_FW_UPGRADE/GPIO7_*
|
||||
touch $SSD_FW_UPGRADE/GPIO7_pending_upgrade
|
||||
|
||||
echo "$0 `date` SSD upgrade didn’t happened." >> $SSD_UPGRADE_LOG
|
||||
echo "$0 `date` SSD upgrade didn’t happen." >> $SSD_UPGRADE_LOG
|
||||
|
||||
elif [ $SSD_UPGRADE_STATUS1 == "1" ]; then
|
||||
rm -rf $SSD_FW_UPGRADE/GPIO7_*
|
||||
touch $SSD_FW_UPGRADE/GPIO7_low
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty and does not support reboot."
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "If a reboot is required, please perform a soft-/fast-/warm-reboot."
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "The SSD on this unit is faulty. Do not power-cycle/reboot this unit!"
|
||||
logger -p user.crit -t DELL_S6100_SSD_MON "soft-/fast-/warm-reboot is allowed."
|
||||
|
||||
echo "$0 `date` SSD entered loader mode in first mp_64 upgrade." >> $SSD_UPGRADE_LOG
|
||||
|
||||
|
@ -0,0 +1 @@
|
||||
fast-reboot_plugin
|
Reference in New Issue