Backport #9258 to 201911 Why I did it When PSU is powered off, the PSU is still on the switch and the air flow is still the same. In this case, it is not necessary to set FAN speed to 100%. How I did it When PSU is powered of, don't treat it as absent. How to verify it Adjust existing unit test case Add new case in sonic-mgmt Conflicts: platform/mellanox/mlnx-platform-api/sonic_platform/thermal_infos.py
This commit is contained in:
parent
690f8e6919
commit
2b4c8ee330
@ -95,12 +95,12 @@ class PsuInfo(ThermalPolicyInfoBase):
|
||||
"""
|
||||
self._status_changed = False
|
||||
for psu in chassis.get_all_psus():
|
||||
if psu.get_presence() and psu.get_powergood_status() and psu not in self._presence_psus:
|
||||
if psu.get_presence() and psu not in self._presence_psus:
|
||||
self._presence_psus.add(psu)
|
||||
self._status_changed = True
|
||||
if psu in self._absence_psus:
|
||||
self._absence_psus.remove(psu)
|
||||
elif (not psu.get_presence() or not psu.get_powergood_status()) and psu not in self._absence_psus:
|
||||
elif (not psu.get_presence()) and psu not in self._absence_psus:
|
||||
self._absence_psus.add(psu)
|
||||
self._status_changed = True
|
||||
if psu in self._presence_psus:
|
||||
|
@ -81,9 +81,9 @@ def test_psu_info():
|
||||
|
||||
psu_list[0].powergood = False
|
||||
psu_info.collect(chassis)
|
||||
assert len(psu_info.get_absence_psus()) == 1
|
||||
assert len(psu_info.get_presence_psus()) == 0
|
||||
assert psu_info.is_status_changed()
|
||||
assert len(psu_info.get_absence_psus()) == 0
|
||||
assert len(psu_info.get_presence_psus()) == 1
|
||||
assert not psu_info.is_status_changed()
|
||||
|
||||
|
||||
def test_fan_policy(thermal_manager):
|
||||
|
Loading…
Reference in New Issue
Block a user