2018-07-03 19:10:11 -05:00
|
|
|
# libsensors configuration file for DCS-7260CX3-64
|
|
|
|
# ------------------------------------------------
|
|
|
|
|
|
|
|
bus "i2c-6" "SCD 0000:06:00.0 SMBus master 0 bus 5"
|
|
|
|
bus "i2c-7" "SCD 0000:06:00.0 SMBus master 0 bus 6"
|
|
|
|
bus "i2c-8" "SCD 0000:06:00.0 SMBus master 0 bus 7"
|
|
|
|
bus "i2c-81" "SCD 0000:ff:0b.3 SMBus master 0 bus 0"
|
|
|
|
bus "i2c-93" "SCD 0000:ff:0b.3 SMBus master 3 bus 0"
|
|
|
|
bus "i2c-96" "SCD 0000:ff:0b.3 SMBus master 3 bus 3"
|
|
|
|
|
|
|
|
chip "max6658-i2c-8-4c"
|
|
|
|
label temp1 "Temp sensor near ASIC"
|
|
|
|
|
|
|
|
set temp1_max 100
|
|
|
|
set temp1_crit 110
|
2018-12-04 12:08:55 -06:00
|
|
|
set temp1_min -55
|
2018-07-03 19:10:11 -05:00
|
|
|
|
2018-12-04 12:08:55 -06:00
|
|
|
set temp2_max 100
|
|
|
|
set temp2_crit 110
|
|
|
|
set temp2_min -55
|
2018-07-03 19:10:11 -05:00
|
|
|
ignore temp2
|
|
|
|
|
|
|
|
chip "dps1900-i2c-6-58"
|
|
|
|
label temp1 "PSU1 primary hotspot temp"
|
|
|
|
label temp2 "PSU1 inlet temp"
|
|
|
|
label temp3 "PSU1 exhaust temp"
|
|
|
|
|
|
|
|
# setting maximum and critical thresholds is not supported for this psu
|
|
|
|
# fault and warning limits defined internally by hardware
|
|
|
|
|
|
|
|
ignore fan2
|
|
|
|
ignore fan3
|
|
|
|
|
|
|
|
chip "dps1900-i2c-7-58"
|
|
|
|
label temp1 "PSU2 primary hotspot temp"
|
|
|
|
label temp2 "PSU2 inlet temp"
|
|
|
|
label temp3 "PSU2 exhaust temp"
|
|
|
|
|
|
|
|
# setting maximum and critical thresholds is not supported for this psu
|
|
|
|
# fault and warning limits defined internally by hardware
|
|
|
|
|
|
|
|
ignore fan2
|
|
|
|
ignore fan3
|
|
|
|
|
|
|
|
chip "max6658-i2c-81-4c"
|
|
|
|
label temp1 "Rear air temp1"
|
|
|
|
label temp2 "Rear air temp2"
|
|
|
|
|
2018-12-04 12:08:55 -06:00
|
|
|
set temp1_max 70
|
|
|
|
set temp1_crit 80
|
|
|
|
set temp1_min -55
|
|
|
|
set temp2_max 70
|
|
|
|
set temp2_crit 80
|
|
|
|
set temp2_min -55
|
2018-07-03 19:10:11 -05:00
|
|
|
|
|
|
|
chip "lm73-i2c-96-48"
|
|
|
|
label temp1 "Front air temp"
|
|
|
|
|
|
|
|
set temp1_max 65
|