2022-11-30 11:47:50 -06:00
|
|
|
##################################################################################
|
|
|
|
# Copyright (c) 2019 - 2022, NVIDIA CORPORATION & AFFILIATES. All rights reserved.
|
|
|
|
#
|
|
|
|
# Platform specific sensors config for SN5600
|
|
|
|
##################################################################################
|
|
|
|
|
|
|
|
# Bus names
|
|
|
|
bus "i2c-39" "i2c-1-mux (chan_id 6)"
|
|
|
|
|
|
|
|
# Temperature sensors
|
|
|
|
chip "mlxsw-i2c-*-48"
|
|
|
|
label temp1 "Ambient ASIC Temp"
|
|
|
|
|
|
|
|
chip "tmp102-i2c-*-49"
|
|
|
|
label temp1 "Ambient Fan Side Temp (air intake)"
|
|
|
|
chip "adt75-i2c-*-49"
|
|
|
|
label temp1 "Ambient Fan Side Temp (air intake)"
|
|
|
|
chip "tmp102-i2c-*-4a"
|
|
|
|
label temp1 "Ambient Port Side Temp (air exhaust)"
|
|
|
|
chip "adt75-i2c-*-4a"
|
|
|
|
label temp1 "Ambient Port Side Temp (air exhaust)"
|
|
|
|
|
|
|
|
# Power controllers
|
|
|
|
chip "mp2975-i2c-*-62"
|
|
|
|
label in1 "PMIC-1 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-1 VDD_M ADJ Rail (out1)"
|
|
|
|
ignore in3
|
|
|
|
label temp1 "PMIC-1 VDD_M ADJ Temp 1"
|
|
|
|
ignore temp2
|
|
|
|
label power1 "PMIC-1 13V5 VDD_M (in)"
|
|
|
|
label power2 "PMIC-1 VDD_M Rail Pwr (out1)"
|
|
|
|
ignore power3
|
|
|
|
label curr1 "PMIC-1 13V5 VDD_M Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-1 VDD_M Rail Curr (out1)"
|
|
|
|
ignore curr3
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
|
|
|
ignore curr7
|
|
|
|
ignore curr8
|
|
|
|
ignore curr9
|
|
|
|
ignore curr10
|
|
|
|
chip "mp2975-i2c-*-63"
|
|
|
|
label in1 "PMIC-2 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-2 VDD_T0 ADJ Rail (out1)"
|
|
|
|
label in3 "PMIC-2 VDD_T1 ADJ Rail (out2)"
|
|
|
|
label temp1 "PMIC-2 VDD_T0 ADJ Temp 1"
|
|
|
|
label temp2 "PMIC-2 VDD_T1 ADJ Temp 2"
|
|
|
|
label power1 "PMIC-2 13V5 VDD_T0 VDD_T1 (in)"
|
|
|
|
label power2 "PMIC-2 VDD_T0 Rail Pwr (out1)"
|
|
|
|
label power3 "PMIC-2 VDD_T1 Rail Pwr (out2)"
|
|
|
|
label curr1 "PMIC-2 13V5 VDD_T0 VDD_T1 Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-2 VDD_T0 Rail Curr (out1)"
|
|
|
|
label curr3 "PMIC-2 VDD_T1 Rail Curr (out2)"
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
|
|
|
chip "mp2975-i2c-*-64"
|
|
|
|
label in1 "PMIC-3 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-3 VDD_T2 ADJ Rail (out1)"
|
|
|
|
label in3 "PMIC-3 VDD_T3 ADJ Rail (out2)"
|
|
|
|
label temp1 "PMIC-3 VDD_T2 ADJ Temp 1"
|
|
|
|
label temp2 "PMIC-3 VDD_T3 ADJ Temp 2"
|
|
|
|
label power1 "PMIC-3 13V5 VDD_T2 VDD_T3 (in)"
|
|
|
|
label power2 "PMIC-3 VDD_T2 Rail Pwr (out1)"
|
|
|
|
label power3 "PMIC-3 VDD_T3 Rail Pwr (out2)"
|
|
|
|
label curr1 "PMIC-3 13V5 VDD_T2 VDD_T3 Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-3 VDD_T2 Rail Curr (out1)"
|
|
|
|
label curr3 "PMIC-3 VDD_T3 Rail Curr (out2)"
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
|
|
|
chip "mp2975-i2c-*-65"
|
|
|
|
label in1 "PMIC-4 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-4 VDD_T4 ADJ Rail (out1)"
|
|
|
|
label in3 "PMIC-4 VDD_T5 ADJ Rail (out2)"
|
|
|
|
label temp1 "PMIC-4 VDD_T4 ADJ Temp 1"
|
|
|
|
label temp2 "PMIC-4 VDD_T5 ADJ Temp 2"
|
|
|
|
label power1 "PMIC-4 13V5 VDD_T4 VDD_T5 (in)"
|
|
|
|
label power2 "PMIC-4 VDD_T4 Rail Pwr (out1)"
|
|
|
|
label power3 "PMIC-4 VDD_T5 Rail Pwr (out2)"
|
|
|
|
label curr1 "PMIC-4 13V5 VDD_T4 VDD_T5 Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-4 VDD_T4 Rail Curr (out1)"
|
|
|
|
label curr3 "PMIC-4 VDD_T5 Rail Curr (out2)"
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
|
|
|
chip "mp2975-i2c-*-66"
|
|
|
|
label in1 "PMIC-5 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-5 VDD_T6 ADJ Rail (out1)"
|
|
|
|
label in3 "PMIC-5 VDD_T7 ADJ Rail (out2)"
|
|
|
|
label temp1 "PMIC-5 VDD_T6 ADJ Temp 1"
|
|
|
|
label temp2 "PMIC-5 VDD_T7 ADJ Temp 2"
|
|
|
|
label power1 "PMIC-5 13V5 VDD_T6 VDD_T7 (in)"
|
|
|
|
label power2 "PMIC-5 VDD_T6 Rail Pwr (out1)"
|
|
|
|
label power3 "PMIC-5 VDD_T7 Rail Pwr (out2)"
|
|
|
|
label curr1 "PMIC-5 13V5 VDD_T6 VDD_T7 Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-5 VDD_T6 Rail Curr (out1)"
|
|
|
|
label curr3 "PMIC-5 VDD_T7 Rail Curr (out2)"
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
|
|
|
chip "mp2975-i2c-*-67"
|
|
|
|
label in1 "PMIC-6 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-6 DVDD_T0 ADJ Rail (out1)"
|
|
|
|
label in3 "PMIC-6 DVDD_T1 ADJ Rail (out2)"
|
|
|
|
label temp1 "PMIC-6 DVDD_T0 ADJ Temp 1"
|
|
|
|
label temp2 "PMIC-6 DVDD_T1 ADJ Temp 2"
|
|
|
|
label power1 "PMIC-6 13V5 DVDD_T0 DVDD_T1 (in)"
|
|
|
|
label power2 "PMIC-6 DVDD_T0 Rail Pwr (out1)"
|
|
|
|
label power3 "PMIC-6 DVDD_T1 Rail Pwr (out2)"
|
|
|
|
label curr1 "PMIC-6 13V5 DVDD_T0 DVDD_T1 Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-6 DVDD_T0 Rail Curr (out1)"
|
|
|
|
label curr3 "PMIC-6 DVDD_T1 Rail Curr (out2)"
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
|
|
|
chip "mp2975-i2c-*-68"
|
|
|
|
label in1 "PMIC-7 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-7 DVDD_T2 ADJ Rail (out1)"
|
|
|
|
label in3 "PMIC-7 DVDD_T3 ADJ Rail (out2)"
|
|
|
|
label temp1 "PMIC-7 DVDD_T2 ADJ Temp 1"
|
|
|
|
label temp2 "PMIC-7 DVDD_T3 ADJ Temp 2"
|
|
|
|
label power1 "PMIC-7 13V5 DVDD_T2 DVDD_T3 (in)"
|
|
|
|
label power2 "PMIC-7 DVDD_T2 Rail Pwr (out1)"
|
|
|
|
label power3 "PMIC-7 DVDD_T3 Rail Pwr (out2)"
|
|
|
|
label curr1 "PMIC-7 13V5 DVDD_T2 DVDD_T3 Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-7 DVDD_T2 Rail Curr (out1)"
|
|
|
|
label curr3 "PMIC-7 DVDD_T3 Rail Curr (out2)"
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
|
|
|
chip "mp2975-i2c-*-69"
|
|
|
|
label in1 "PMIC-8 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-8 DVDD_T4 ADJ Rail (out1)"
|
|
|
|
label in3 "PMIC-8 DVDD_T5 ADJ Rail (out2)"
|
|
|
|
label temp1 "PMIC-8 DVDD_T4 ADJ Temp 1"
|
|
|
|
label temp2 "PMIC-8 DVDD_T5 ADJ Temp 2"
|
|
|
|
label power1 "PMIC-8 13V5 DVDD_T4 DVDD_T5 (in)"
|
|
|
|
label power2 "PMIC-8 DVDD_T4 Rail Pwr (out1)"
|
|
|
|
label power3 "PMIC-8 DVDD_T5 Rail Pwr (out2)"
|
|
|
|
label curr1 "PMIC-8 13V5 DVDD_T4 DVDD_T5 Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-8 DVDD_T4 Rail Curr (out1)"
|
|
|
|
label curr3 "PMIC-8 DVDD_T5 Rail Curr (out2)"
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
|
|
|
chip "mp2975-i2c-*-6a"
|
|
|
|
label in1 "PMIC-9 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-9 DVDD_T6 ADJ Rail (out1)"
|
|
|
|
label in3 "PMIC-9 DVDD_T7 ADJ Rail (out2)"
|
|
|
|
label temp1 "PMIC-9 DVDD_T6 ADJ Temp 1"
|
|
|
|
label temp2 "PMIC-9 DVDD_T7 ADJ Temp 2"
|
|
|
|
label power1 "PMIC-9 13V5 DVDD_T6 DVDD_T7 (in)"
|
|
|
|
label power2 "PMIC-9 DVDD_T6 Rail Pwr (out1)"
|
|
|
|
label power3 "PMIC-9 DVDD_T7 Rail Pwr (out2)"
|
|
|
|
label curr1 "PMIC-9 13V5 DVDD_T6 DVDD_T7 Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-9 DVDD_T6 Rail Curr (out1)"
|
|
|
|
label curr3 "PMIC-9 DVDD_T7 Rail Curr (out2)"
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
2023-05-02 02:36:57 -05:00
|
|
|
chip "mp2975-i2c-*-6c"
|
2022-11-30 11:47:50 -06:00
|
|
|
label in1 "PMIC-10 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-10 HVDD_T03 1V2 Rail (out1)"
|
|
|
|
label in3 "PMIC-10 HVDD_T47 1V2 Rail (out2)"
|
|
|
|
label temp1 "PMIC-10 HVDD_T03 1V2 Temp 1"
|
|
|
|
label temp2 "PMIC-10 HVDD_T47 1V2 Temp 2"
|
|
|
|
label power1 "PMIC-10 13V5 HVDD_T03 HVDD_T47 (in)"
|
|
|
|
label power2 "PMIC-10 HVDD_T03 Rail Pwr (out1)"
|
|
|
|
label power3 "PMIC-10 HVDD_T47 Rail Pwr (out2)"
|
|
|
|
label curr1 "PMIC-10 13V5 HVDD_T03 HVDD_T47 Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-10 HVDD_T03 Rail Curr (out1)"
|
|
|
|
label curr3 "PMIC-10 HVDD_T47 Rail Curr (out2)"
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
|
|
|
ignore curr7
|
|
|
|
ignore curr8
|
|
|
|
ignore curr9
|
|
|
|
ignore curr10
|
|
|
|
ignore curr11
|
|
|
|
chip "mp2975-i2c-*-6e"
|
|
|
|
label in1 "PMIC-11 PSU 13V5 Rail (in1)"
|
|
|
|
label in2 "PMIC-11 VDDSCC 0V75 Rail (out1)"
|
|
|
|
label in3 "PMIC-11 DVDD_M ADJ Rail (out2)"
|
|
|
|
label temp1 "PMIC-11 VDDSCC 1V2 Temp 1"
|
|
|
|
label temp2 "PMIC-11 DVDD_M 1V2 Temp 2"
|
|
|
|
label power1 "PMIC-11 13V5 VDDSCC DVDD_M (in)"
|
|
|
|
label power2 "PMIC-11 VDDSCC Rail Pwr (out1)"
|
|
|
|
label power3 "PMIC-11 DVDD_M Rail Pwr (out2)"
|
|
|
|
label curr1 "PMIC-11 13V5 VDDSCC DVDD_M Rail Curr (in1)"
|
|
|
|
label curr2 "PMIC-11 VDDSCC Rail Curr (out1)"
|
|
|
|
label curr3 "PMIC-11 DVDD_M Rail Curr (out2)"
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
ignore curr6
|
|
|
|
|
|
|
|
# Power supplies
|
|
|
|
|
2023-05-02 02:36:57 -05:00
|
|
|
chip "dps460-i2c-*-59"
|
2022-11-30 11:47:50 -06:00
|
|
|
label in1 "PSU-1(L) 220V Rail (in)"
|
|
|
|
ignore in2
|
|
|
|
label in3 "PSU-1(L) 12V Rail (out)"
|
|
|
|
label fan1 "PSU-1(L) Fan 1"
|
|
|
|
label temp1 "PSU-1(L) Temp 1"
|
|
|
|
label temp2 "PSU-1(L) Temp 2"
|
|
|
|
label temp3 "PSU-1(L) Temp 3"
|
|
|
|
label power1 "PSU-1(L) 220V Rail Pwr (in)"
|
|
|
|
label power2 "PSU-1(L) 12V Rail Pwr (out)"
|
|
|
|
label curr1 "PSU-1(L) 220V Rail Curr (in)"
|
|
|
|
label curr2 "PSU-1(L) 12V Rail Curr (out)"
|
2023-05-02 02:36:57 -05:00
|
|
|
set power2_cap 0
|
|
|
|
chip "dps460-i2c-*-5a"
|
2022-11-30 11:47:50 -06:00
|
|
|
label in1 "PSU-2(R) 220V Rail (in)"
|
|
|
|
ignore in2
|
|
|
|
label in3 "PSU-2(R) 12V Rail (out)"
|
|
|
|
label fan1 "PSU-2(R) Fan 1"
|
|
|
|
label temp1 "PSU-2(R) Temp 1"
|
|
|
|
label temp2 "PSU-2(R) Temp 2"
|
|
|
|
label temp3 "PSU-2(R) Temp 3"
|
|
|
|
label power1 "PSU-2(R) 220V Rail Pwr (in)"
|
|
|
|
label power2 "PSU-2(R) 12V Rail Pwr (out)"
|
|
|
|
label curr1 "PSU-2(R) 220V Rail Curr (in)"
|
|
|
|
label curr2 "PSU-2(R) 12V Rail Curr (out)"
|
|
|
|
|
|
|
|
# Power converters
|
|
|
|
chip "pmbus-i2c-*-10"
|
|
|
|
label in1 "IBC-1 PWR CONV 54V Rail (in1)"
|
|
|
|
ignore in2
|
|
|
|
ignore in3
|
|
|
|
label temp1 "IBC-1 Temp 1"
|
2023-05-02 02:36:57 -05:00
|
|
|
ignore curr1
|
|
|
|
label curr2 "IBC-1 13V5 Rail Curr (out)"
|
2022-11-30 11:47:50 -06:00
|
|
|
chip "pmbus-i2c-*-11"
|
|
|
|
label in1 "IBC-2 PWR CONV 54V Rail (in1)"
|
|
|
|
ignore in2
|
|
|
|
ignore in3
|
|
|
|
label temp1 "IBC-2 Temp 1"
|
|
|
|
label curr1 "IBC-2 13V5 Rail Curr (out)"
|
|
|
|
ignore curr2
|
|
|
|
chip "pmbus-i2c-*-13"
|
|
|
|
label in1 "IBC-3 PWR CONV 54V Rail (in1)"
|
|
|
|
ignore in2
|
|
|
|
ignore in3
|
|
|
|
label temp1 "IBC-3 Temp 1"
|
|
|
|
label curr1 "IBC-3 13V5 Rail Curr (out)"
|
|
|
|
ignore curr2
|
|
|
|
chip "pmbus-i2c-*-15"
|
|
|
|
label in1 "IBC-4 PWR CONV 54V Rail (in1)"
|
|
|
|
ignore in2
|
|
|
|
ignore in3
|
|
|
|
label temp1 "IBC-4 Temp 1"
|
|
|
|
label curr1 "IBC-4 13V5 Rail Curr (out)"
|
|
|
|
ignore curr2
|
|
|
|
|
|
|
|
#COMEX CFL
|
|
|
|
chip "mp2975-i2c-39-6b"
|
|
|
|
label in1 "PMIC-6 PSU 12V Rail (vin)"
|
|
|
|
label in2 "PMIC-6 COMEX VCORE (out1)"
|
|
|
|
label in3 "PMIC-6 COMEX VCCSA (out2)"
|
|
|
|
label temp1 "PMIC-6 Temp"
|
|
|
|
label power1 "PMIC-6 COMEX Pwr (pin)"
|
|
|
|
label power2 "PMIC-6 COMEX VCORE Pwr (pout1)"
|
|
|
|
label power3 "PMIC-6 COMEX VCCSA Pwr (pout2)"
|
|
|
|
label curr1 "PMIC-6 COMEX Curr (iin)"
|
|
|
|
label curr2 "PMIC-6 COMEX VCORE Rail Curr (out1)"
|
|
|
|
ignore curr3
|
|
|
|
ignore curr4
|
|
|
|
ignore curr5
|
|
|
|
label curr6 "PMIC-6 COMEX VCCSA Rail Curr (out2)"
|
|
|
|
ignore curr7
|
|
|
|
|
|
|
|
# Chassis fans
|
|
|
|
chip "mlxreg_fan-isa-*"
|
|
|
|
label fan1 "Chassis Fan Drawer-1 Tach 1"
|
|
|
|
label fan2 "Chassis Fan Drawer-1 Tach 2"
|
|
|
|
label fan3 "Chassis Fan Drawer-2 Tach 1"
|
|
|
|
label fan4 "Chassis Fan Drawer-2 Tach 2"
|
|
|
|
label fan5 "Chassis Fan Drawer-3 Tach 1"
|
|
|
|
label fan6 "Chassis Fan Drawer-3 Tach 2"
|
|
|
|
label fan7 "Chassis Fan Drawer-4 Tach 1"
|
|
|
|
label fan8 "Chassis Fan Drawer-4 Tach 2"
|
|
|
|
|
|
|
|
# Memory sensors
|
|
|
|
bus "i2c-0" "SMBus I801 adapter at efa0"
|
|
|
|
chip "jc42-i2c-0-1c"
|
|
|
|
label temp1 "SODIMM Temp"
|
|
|
|
|
|
|
|
chip "jc42-i2c-0-1a"
|
|
|
|
label temp1 "SODIMM Temp"
|
|
|
|
|
|
|
|
# PCH
|
|
|
|
chip "pch_cannonlake-virtual-*"
|
|
|
|
label temp1 "PCH Temp"
|
|
|
|
|
|
|
|
# SSD
|
|
|
|
chip "drivetemp-*"
|
|
|
|
label temp1 "SSD Temp"
|
|
|
|
|
|
|
|
chip "*-acpi-*"
|
|
|
|
label temp1 "CPU ACPI temp"
|