sonic-buildimage/device/arista/x86_64-arista_7050cx3_32s/sensors.conf

40 lines
1.1 KiB
Plaintext
Raw Normal View History

# libsensors configuration file for DCS-7050CX3-32S
# ------------------------------------------------
#
bus "i2c-2" "SCD 0000:02:00.0 SMBus master 0 bus 0"
bus "i2c-11" "SCD 0000:02:00.0 SMBus master 1 bus 1"
bus "i2c-13" "SCD 0000:02:00.0 SMBus master 1 bus 3"
bus "i2c-14" "SCD 0000:02:00.0 SMBus master 1 bus 4"
chip "k10temp-pci-00c3"
label temp1 "Cpu temp sensor"
chip "max6658-i2c-2-4c"
label temp1 "Cpu board temp sensor"
set temp1_max 75
set temp1_crit 80
label temp2 "Back panel temp sensor"
set temp2_max 75
set temp2_crit 85
chip "max6658-i2c-11-4c"
label temp1 "Board temp sensor"
set temp1_max 55
set temp1_crit 70
label temp2 "Front panel temp sensor"
set temp2_max 60
set temp2_crit 65
chip "pmbus-i2c-13-58"
label temp1 "Power supply 1 hotspot sensor"
label temp2 "Power supply 1 inlet temp sensor"
label temp3 "Power supply 1 sensor"
chip "pmbus-i2c-14-58"
label temp1 "Power supply 2 hotspot sensor"
label temp2 "Power supply 2 inlet temp sensor"
label temp3 "Power supply 2 sensor"