sonic-buildimage/platform/broadcom/sonic-platform-modules-accton/as7315-27xb/classes/fanutil.py

235 lines
7.9 KiB
Python
Raw Normal View History

#!/usr/bin/env python
#
# Copyright (C) 2017 Accton Technology Corporation
#
# This program is free software: you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation, either version 3 of the License, or
# (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program. If not, see <http://www.gnu.org/licenses/>.
# ------------------------------------------------------------------
# HISTORY:
# mm/dd/yyyy (A.D.)
# 11/13/2017: Polly Hsu, Create
# 1/10/2018: Jostar modify for as7716_32
# 5/02/2019: Roy Lee modify for as7816_64x
# ------------------------------------------------------------------
try:
import time
import logging
from collections import namedtuple
import subprocess
except ImportError as e:
raise ImportError('%s - required module not found' % str(e))
class FanUtil(object):
"""Platform-specific FanUtil class"""
FAN_TOTAL_NUM = 5
FAN_NUM_1_IDX = 1
FAN_NODE_NUM = 2
FAN_FAULT_IDX = 1
#FAN_SPEED_IDX = 2
FAN_DIR_IDX = 2
#FAN_NODE_DUTY_IDX_OF_MAP = 4
#FANR_NODE_FAULT_IDX_OF_MAP = 5
I2CADDR_CANDIDATES = ((9, 66), # for R0C HW and later
(50, 66)) # for R0A, R0B HW
PATH_PREFIX = '/sys/bus/i2c/devices/{}-00{}/'
BASE_VAL_PATH = '{0}'
FAN_DUTY_PATH = 'fan{0}_pwm'
#logfile = ''
#loglevel = self.logger.INFO
""" Dictionary where
key1 = fan id index (integer) starting from 1
key2 = fan node index (interger) starting from 1
value = path to fan device file (string) """
dev_paths = {}
node_postfix = ["fault", "direction"]
def _get_fan_to_device_node(self, fan_num, node_num):
return "fan{0}_{1}".format(fan_num, self.node_postfix[node_num-1])
def _get_fan_i2c_bus_addr(self):
cmd_template = 'i2cget -f -y {} 0x{} 0'
for bus_no, dev_addr in self.I2CADDR_CANDIDATES:
cmd = cmd_template.format(bus_no, dev_addr)
if subprocess.getstatusoutput(cmd)[0] == 0:
return bus_no, dev_addr
raise IOError('Unable to reach fan CPLD via I2C')
def _init_fnode_basepath(self):
'''format BASE_VAL_PATH and FAN_DUTY_PATH '''
bus, addr = self._get_fan_i2c_bus_addr()
self.PATH_PREFIX = self.PATH_PREFIX.format(bus, addr)
self.BASE_VAL_PATH = self.PATH_PREFIX + self.BASE_VAL_PATH
self.FAN_DUTY_PATH = self.PATH_PREFIX + self.FAN_DUTY_PATH
def _get_fan_node_val(self, fan_num, node_num):
if fan_num < self.FAN_NUM_1_IDX or fan_num > self.FAN_TOTAL_NUM:
self.logger.debug('GET. Parameter error. fan_num:%d', fan_num)
return None
if node_num < self.FAN_FAULT_IDX or node_num > self.FAN_NODE_NUM:
self.logger.debug('GET. Parameter error. node_num:%d', node_num)
return None
device_path = self.get_fan_to_device_path(fan_num, node_num)
try:
val_file = open(device_path, 'r')
except IOError as e:
self.logger.error('GET. unable to open file: %s', str(e))
return None
content = val_file.readline().rstrip()
if content == '':
self.logger.debug('GET. content is NULL. device_path:%s', device_path)
return None
try:
val_file.close()
except:
self.logger.debug('GET. unable to close file. device_path:%s', device_path)
return None
return int(content)
def _set_fan_node_val(self, fan_num, node_num, val):
if fan_num < self.FAN_NUM_1_IDX or fan_num > self.FAN_TOTAL_NUM:
self.logger.debug('GET. Parameter error. fan_num:%d', fan_num)
return None
if node_num < self.FAN_FAULT_IDX or node_num > self.FAN_NODE_NUM:
self.logger.debug('GET. Parameter error. node_num:%d', node_num)
return None
content = str(val)
if content == '':
self.logger.debug('GET. content is NULL. device_path:%s', device_path)
return None
device_path = self.get_fan_to_device_path(fan_num, node_num)
try:
val_file = open(device_path, 'w')
except IOError as e:
self.logger.error('GET. unable to open file: %s', str(e))
return None
val_file.write(content)
try:
val_file.close()
except:
self.logger.debug('GET. unable to close file. device_path:%s', device_path)
return None
return True
logger = logging.getLogger(__name__)
def __init__(self, log_level=logging.DEBUG):
ch = logging.StreamHandler()
ch.setLevel(log_level)
self.logger.addHandler(ch)
self._init_fnode_basepath()
fan_path = self.BASE_VAL_PATH
for fan_num in range(self.FAN_NUM_1_IDX, self.FAN_TOTAL_NUM+1):
for node_num in range(1, self.FAN_NODE_NUM+1):
node = self._get_fan_to_device_node(fan_num, node_num)
self.dev_paths[(fan_num, node_num)] = fan_path.format(node)
def get_num_fans(self):
return self.FAN_TOTAL_NUM
def get_idx_fan_start(self):
return self.FAN_NUM_1_IDX
def get_num_nodes(self):
return self.FAN_NODE_NUM
def get_idx_node_start(self):
return self.FAN_FAULT_IDX
def get_size_node_map(self):
return len(self.dev_paths)
def get_size_path_map(self):
return len(self.dev_paths)
def get_fan_to_device_path(self, fan_num, node_num):
return self.dev_paths[(fan_num, node_num)]
def get_fan_fault(self, fan_num):
return self._get_fan_node_val(fan_num, self.FAN_FAULT_IDX)
#def get_fan_speed(self, fan_num):
# return self._get_fan_node_val(fan_num, self.FAN_SPEED_IDX)
def get_fan_dir(self, fan_num):
return self._get_fan_node_val(fan_num, self.FAN_DIR_IDX)
def get_fan_duty_cycle(self):
try:
val_file = open(self.FAN_DUTY_PATH.format(1))
except IOError as e:
print("Error: unable to open file: %s" % str(e))
return False
content = val_file.readline().rstrip()
val_file.close()
return int(content)
def set_fan_duty_cycle(self, val):
for fan_num in range(1, self.FAN_TOTAL_NUM+1):
try:
fan_file = open(self.FAN_DUTY_PATH.format(fan_num), 'r+')
except IOError as e:
print("Error: unable to open file: %s" % str(e))
return False
fan_file.write(str(val))
fan_file.close()
return True
def get_fan_status(self, fan_num):
if fan_num < self.FAN_NUM_1_IDX or fan_num > self.FAN_TOTAL_NUM:
self.logger.debug('GET. Parameter error. fan_num, %d', fan_num)
return None
if self.get_fan_fault(fan_num) is not None and self.get_fan_fault(fan_num) > 0:
self.logger.debug('GET. FAN fault. fan_num, %d', fan_num)
return False
#if self.get_fanr_fault(fan_num) is not None and self.get_fanr_fault(fan_num) > 0:
# self.logger.debug('GET. FANR fault. fan_num, %d', fan_num)
# return False
return True
#def main():
# fan = FanUtil()
#
# print 'get_size_node_map : %d' % fan.get_size_node_map()
# print 'get_size_path_map : %d' % fan.get_size_path_map()
# for x in range(fan.get_idx_fan_start(), fan.get_num_fans()+1):
# for y in range(fan.get_idx_node_start(), fan.get_num_nodes()+1):
# print fan.get_fan_to_device_path(x, y)
#
#if __name__ == '__main__':
# main()